-
Reagents
- Flow Cytometry Reagents
-
Western Blotting and Molecular Reagents
-
Flow Cytometry Reagents
- Immunoassay Reagents
- Single Cell Multiomics Reagents
-
Cell Preparation
-
Functional Assays
-
Microscopy and Imaging Reagents
- Western Blotting And Molecular Reagents
- Cell Preparation Separation Reagents
- Functional Cell Based Reagents
- Microscopy Imaging Reagents
- Single Cell Multiomics Reagents
- Single Cell Multinomics Reagents
-
Protocols
- BSB Protocol
-
Setting Compensation Multicolor Flow
-
Tissues Section Stain
-
Immunomicroscopy
-
Immunohistochemical
-
Immunofluorescence
-
Frozen Tissue
-
Parafin Sections
-
Fix Perm Kits
-
Protocol Direct Immunofluorscence Staining
-
Uses of Fc Block
-
Stain Lyse Wash
-
Stain Lyse No Wash
-
Mouse Splenocytes
-
Mouse Rat Leukocytes
-
Isotype Control
-
Indirect Staining Mononuclear Cells
-
Immunopurification
-
Human PBMCs
-
Human Whole Blood Samples
-
Escapee Phenomenon
-
Agarose Conjugates
-
Anti Phosphotyrosine Biotin Conjugates
-
Soluble Antibodies
-
Rabbit Polyclonal Antibodies
-
Monocloncal Antibodies
-
Horseradish Peroxidase
-
Certified Reagents
-
Biotinylated Antibodies
-
Agarose Conjugates X712261
-
Surface Staining
-
Platelet Activation
-
Intracellular Staining
-
Indirect Immunofluorescence
-
Mouse Ige
-
Cytokine Elisa
-
Induction Fas
-
Induction Dx2
-
Apoptosis By Treatment Staurosporine
-
Cell Death
-
Apo Brdu
-
Apo Direct
-
Human Cyclins
-
Detection Ki 67
-
Brdu Detection
-
Targeted mRNA Protocols
-
WTA Protocols
-
360040667732 Protocols
-
360023293831 AbSeq Protocols
-
360039007471 VDJ CDR3 Protocols
-
Annexin V Staining Protocol
-
Western Blotting with Horseradish Peroxidase Conjugates or Alkaline Phosphatase Conjugates
-
Tissue Preparation for Surface Antigen Staining
-
Account Support
-
Account FAQs
- Account FAQ Answer 1
- Account FAQ Answer 2
- Account FAQ Answer 3
- Account FAQ Answer 4
- Account FAQ Answer 5
- Account FAQ Answer 6
- Account FAQ Answer 7
- Account FAQ Answer 8
- Account FAQ Answer 9
- Account FAQ Answer 10
- Account FAQ Answer 11
- Account FAQ Answer 12
- Account FAQ Answer 13
- Account FAQ Answer 14
- Account FAQ Answer 15
- Account FAQ Answer 16
- Account FAQ Answer 21
- Create Account
- Manage Account Settings
-
PrivacyPolicy
-
Terms and Conditions
-
Account FAQs
-
- Account FAQ Answer 1
- Account FAQ Answer 2
- Account FAQ Answer 3
- Account FAQ Answer 4
- Account FAQ Answer 5
- Account FAQ Answer 6
- Account FAQ Answer 7
- Account FAQ Answer 8
- Account FAQ Answer 9
- Account FAQ Answer 10
- Account FAQ Answer 11
- Account FAQ Answer 12
- Account FAQ Answer 13
- Account FAQ Answer 14
- Account FAQ Answer 15
- Account FAQ Answer 16
- Account FAQ Answer 21
- Korea (English)
- Korea (Korea)
- 국가 / 언어 변경
Old Browser
Overview
The BD LSRFortessa™ X-20 Cell Analyzer can be configured with up to 5 lasers to detect up to 20 parameters simultaneously to support ever increasing demands in multicolor flow cytometry.
BD FACSDiva™ Software controls the efficient setup, acquisition and analysis of flow cytometry data from the BD LSRFortessa™ Workstation. This software is common across BD FACS™ instrument families, including the BD FACSCanto™ Cell Analyzer and BD FACSAria™ Cell Sorter systems. This affords greater application flexibility and allows you to easily move assays from one platform to another.
Take advantage of the multicolor panels designed for various applications, such as immunopheotyping, characterization of stem cells, identification of human mesenchymal stromal cell and more, using the BD LSRFortessa™ X-20 Cell Analyzer.
Learn more from the BD LSRFortessa™ X-20 System Brochure.
If you own our legacy BD® LSR II Flow Cytometer, you can take advantage of our exclusive special offers for trading in your BD® LSR II System.
Contact our Technical and Applications Support personnel for maintaining optimal instrument performance and with any other instrument-related support.
FEATURES
The BD LSRFortessa™ X-20 System provides flexibility to meet your research needs
The BD LSRFortessa X-20 System:
- Can be ordered with up to 5 lasers—most commonly blue, red, violet, yellow-green and UV—which provides flexibility in laser wavelengths. This flexibility allows you to optimize assay design by selecting the latest fluorescent dyes and antibodies in experimental protocols
- Can accommodate the detection of up to 18 colors simultaneously with a defined set of optical filters that meet today's assay requirements. Optical capability can be added or upgraded to expand with your lab as future needs arise
- Has a small footprint of 76.2 x 73.7 x 76.2 cm (30 x 29 x 30 in.), allowing it to fit easily on the benchtop for the cost-effective use of valuable laboratory space
- Offers design enhancements that provide easier access to bandpass filters and mirrors, simplifying changes in the instrument configuration
The BD LSRFortessa™ X-20 System’s innovative excitation and collection optics design reduces excitation losses and optimizes collection efficiency for increased sensitivity and resolution
Maximum signal and minimum crosstalk—an innovative and proven platform for multicolor analysis
- The polygon optical detector array maximizes signal detection and increases sensitivity and resolution allowing you to identify dim and rare cell populations
- The optics system uses a novel laser design that illuminates cells in the sample and collection optics that direct light scatter and fluorescence signals through spectral filters to the detectors
Get more information on the excitation and collection optics of the BD LSRFortessa™ System from the system brochure.
The BD LSRFortessa™ X-20 System’s fluidics system features a true fixed alignment flow cell that is gel-coupled to the collection optics to maximize detector signal
- The fluidics design ensures that the laser is precisely focused on the sample stream and maximum amount of emitted light can be collected for added sensitivity in multicolor applications
- Fixed alignment also minimizes startup time, improves experiment-to-experiment reproducibility and enables automated daily quality control
- The sheath container (8 L) and waste container (10 L) are outside the cytometer, positioned on the floor for easy access
- Fluidics sensors maintain constant pressure, while a fluidics monitoring system warns when sheath fluid is low or empty or when the waste container is full
The BD LSRFortessa™ X-20 System offers custom configurations for evolving needs
An Innovative Process
The BD special order program allows you to add lasers after your initial system purchase to meet new or evolving requirements. This wide range of choice and flexibility makes the special-order BD LSRFortessa™ X-20 System a solid long-term investment.
The vigorous sourcing of the latest and best laser technologies ensures an unparalleled range of configuration choices offered by the BD special order program for BD® LSR Cell Analyzers.
New technologies are regularly incorporated into the product line as soon as they become available.
The ever-expanding list of available lasers demonstrates the ongoing commitment by BD to perpetual innovation. This is one of the many ways BD ensures that the BD® LSR Cell Analyzer platform continues to support the evolving needs of leading researchers around the world.
The BD LSRFortessa™ X-20 System provides optimal resolution of cell populations.
The high sensitivity of the BD LSRFortessa™ X-20 Cell Analyzer allows optimal resolution of lower expression antigens and rare cell subsets. In this example, regulatory T cells (Tregs), characterized by low levels of expression of CD127 and high levels of CD25, were easily identified. Note the resolution of different levels of expression of CD25 and CD127.
Characterization of the BD LSRFortessa™ X-20 Cell Analyzer sensitivity using 8-peak beads
The sensitivity across detectors of a BD LSRFortessa™ X-20 Cell Analyzer equipped with blue (50-mW), red (100-mW) and violet (50-mW) lasers is illustrated by the optimal resolution of SPHERO™ Rainbow 8-Peak Beads. Note that all peaks are easily identified in various detectors from the blue (A, B), red (C, D) and violet (E, F) lasers.
APPLICATIONS
Data show a 10-color panel run on a 3-laser BD LSRFortessa™ X-20 Cell Analyzer with a blue/red/violet configuration. The panel was used for defining various subsets of regulatory T cells (A, B), memory/effector CD4+ T cells (C, D, E, F) and memory/effector+ T cells (G, H, I, J).
- Brochures
- Filter Guides
- Technical Specifications
- Data Sheets
- Experiment Sheets
- BD Flow Cytometry Reagents: Multicolor Panels Designed for Optimal Resolution with the BD LSRFortessa™ X-20 Cell Analyzer
- BD LSRFortessa™ X-20 15-Color Immunophenotyping
- BD LSRFortessa™ X-20 System 5-Color Panels Designed for Minimal Compensation
- BD LSRFortessa™ X-20 4-Color Panels Minimal Spectral Overlap
- BD LSRFortessa™ X-20 8-Color Panels for Mesenchymal Stromal Cells
- User's Guides and Manuals
- Quick Reference Guides
- White Paper
Request a Quote
Please fill in the following information and we will get in touch with you regarding your query.
BD flow cytometers are Class I (1) laser products.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.
Purchase does not include or carry any right to resell or transfer this product either as a stand-alone product or as a component of another product. Any use of this product other than the permitted use without the express written authorization of Becton, Dickinson and Company is strictly prohibited. Product availability and prices are subject to change without notice.
Alexa Fluor, Texas Red and Pacific Blue are trademarks of Thermo Fisher Scientific. CF is a trademark of Biotium, Inc. NSG™ and Onco-Hu™ are trademarks of The Jackson Laboratory. Cy is a trademark of Global Life Sciences Solutions Germany GmbH or an affiliate doing business as Cytiva.
23-22855-00
Report a Site Issue
This form is intended to help us improve our website experience. For other support, please visit our Contact Us page.