BD Via-Probe™
Flow cytometry, Immunocytochemistry, Immunofluorescence, Intracellular staining (flow cytometry) (Tested During Development)
5 mM
AB_2869717


Preparation And Storage

Store at -20°C, protected from exposure to light. Avoid multiple freeze-thaws of product.

Recommended Assay Procedures

Please Note: This nucleic acid dye has been developed for the flow cytometry (intracellular) and immunofluorescence microscopy applications. Chemically characterized for consistency, researchers should determine the optimal concentration of this reagent for individual applications.

Staining of Live Cells for Viability Analysis by Flow Cytometry

1.   Obtain a single cell suspension.

2.   Resuspend cells at 1-2 × 10^6 cells/mL in BD Pharmingen™ Stain Buffer (FBS) (Cat. No. 554656) or 1× DPBS containing 5-20 nM BD Via-Probe™ Red.

a.   The optimal concentration of BD Via-Probe™ Red for viability analysis may vary by cell type. Using high concentrations may result in the dye entering viable cells. Therefore, we recommend titrating the reagent for your cell type of interest in preliminary experiments.

b.   Additionally, apoptotic cells may stain with variable amounts of probe. We recommend co-staining with a probe for apoptotic cells, eg, BD Horizon Annexin V (Cat. No. 563973), if further analysis of apoptotic cells is desired.

3.   Incubate the cells and dye for 5 minutes at room temperature protected from light. No further cell washes are necessary prior to analysis.

4.   Proceed to analysis by flow cytometry.

Staining of Fixed Cells for DNA Content Analysis by Flow Cytometry

1.   Obtain a single cell suspension.

2.   Treat cells on ice for 30 minutes with 70 - 80% ice-cold ethanol.

a.   Ethanol fixation typically provides the most resolved DNA histograms. However, this reagent has also been successfully used for DNA content analysis with the BD Pharmingen™ Transcription Factor Buffer Set (Cat. No. 562574/562725) protocol.

3.   Wash cells once with BD Pharmingen™ Stain Buffer (FBS).

4. Resuspend cells at 1-2 × 10^6 cells/mL in 0.1- 1 μM BD Via-Probe™ Red in the presence of 0.1-0.5 mg/mL DNAse-free RNAse (eg, Sigma Aldrich, Cat. No. D6513) diluted in BD Pharmingen™ Stain Buffer (FBS) or 1× DPBS immediately before use.

a.   The optimal cell density and concentration of BD Via-Probe™ Red for DNA content analysis may vary by cell type. Assay conditions should be optimized in preliminary experiments for best results.

5.   Incubate cells for 5-15 minutes. No further cell washes are necessary prior to analysis.

6.   Proceed to analysis by flow cytometry. Samples should be run at a low flow rate to achieve the best results. High flow rates may result in higher % CV for each cell cycle compartment in the DNA histogram.

Immunofluorescent Staining of Fixed Cells for Nuclear Visualization

1.   Fix and permeabilize cells as desired.

2.   Dilute BD Via-Probe™ Red solution to 0.1- 1 μM in 1× DPBS with 0.1-0.5 mg/mL DNase-free RNase (eg, Sigma Aldrich, Cat. No. D6513) immediately prior to use.

3.   Add BD Via-Probe™ Red solution to each sample at least 15 minutes before analysis.

4.   Proceed to fluorescence microscopy and image analysis.

Product Notices

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. Triton is a trademark of the Dow Chemical Company.
  3. FlowJo is a trademark of Tree Star Inc.
  4. Alexa Fluor® is a registered trademark of Molecular Probes, Inc., Eugene, OR.
565804 Rev. 2
Antibody Details
Down Arrow

BD Via-Probe™ Red Nucleic Acid Stain is a nucleic acid dye that is useful for the discrimination of viable from nonviable cells, DNA content analysis in fixed cells, or nuclear counterstaining for fixed cells in immunofluorescence or flow cytometry applications. Although this dye is impermeant to viable cells with intact plasma membranes, it brightly stains nonviable or fixed cells with permeable membranes. BD Via-Probe™ Red Nucleic Acid Stain has an excitation maximum of 631 nm, and is best excited by the red laser. BD Via-Probe™ Red Nucleic Acid Stain has an emission maximum of 651 nm.

565804 Rev. 2
Citations & References
Down Arrow

Development References (4)

  1. Darzynkiewicz Z, Bruno S, Del Bino G, et al. Features of apoptotic cells measured by flow cytometry. Cytometry. 1992; 13(8):795-808. (Methodology: Immunofluorescence, Immunocytochemistry, Flow cytometry, Intracellular staining (flow cytometry)). View Reference
  2. Darzynkiewicz Z, Halicka HD, Zhao H. Analysis of cellular DNA content by flow and laser scanning cytometry.. Adv Exp Med Biol. 2010; 676:137-47. (Methodology: Immunofluorescence, Immunocytochemistry, Flow cytometry, Intracellular staining (flow cytometry)). View Reference
  3. Hotz MA, Gong J, Traganos F, and Darzynkiewicz Z. Flow cytometric detection of apoptosis: Comparison of the assays of in situ DNA degradation and chromatin changes. Cytometry. 1994; 15(3):237-244. (Methodology: Immunofluorescence, Immunocytochemistry, Flow cytometry, Intracellular staining (flow cytometry)). View Reference
  4. Schimenti KJ, Jacobberger JW. Fixation of mammalian cells for flow cytometric evaluation of DNA content and nuclear immunofluorescence.. Cytometry. 1992; 13(1):48-59. (Methodology: Immunofluorescence, Immunocytochemistry, Flow cytometry, Intracellular staining (flow cytometry)). View Reference
View All (4) View Less
565804 Rev. 2

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.