Reagents
- Flow Cytometry Reagents
-
Western Blotting and Molecular Reagents
-
Flow Cytometry Reagents
- Immunoassay Reagents
- Single Cell Multiomics Reagents
-
Cell Preparation
-
Functional Assays
-
Microscopy and Imaging Reagents
- Western Blotting And Molecular Reagents
- Cell Preparation Separation Reagents
- Functional Cell Based Reagents
- Microscopy Imaging Reagents
- Single Cell Multiomics Reagents
- Single Cell Multinomics Reagents
-
Account Support
-
Account FAQs
- Account FAQ Answer 1
- Account FAQ Answer 2
- Account FAQ Answer 3
- Account FAQ Answer 4
- Account FAQ Answer 5
- Account FAQ Answer 6
- Account FAQ Answer 7
- Account FAQ Answer 8
- Account FAQ Answer 9
- Account FAQ Answer 10
- Account FAQ Answer 11
- Account FAQ Answer 12
- Account FAQ Answer 13
- Account FAQ Answer 14
- Account FAQ Answer 15
- Account FAQ Answer 16
- Account FAQ Answer 21
- Create Account
- Manage Account Settings
-
PrivacyPolicy
-
Terms and Conditions
-
Account FAQs
-
- Account FAQ Answer 1
- Account FAQ Answer 2
- Account FAQ Answer 3
- Account FAQ Answer 4
- Account FAQ Answer 5
- Account FAQ Answer 6
- Account FAQ Answer 7
- Account FAQ Answer 8
- Account FAQ Answer 9
- Account FAQ Answer 10
- Account FAQ Answer 11
- Account FAQ Answer 12
- Account FAQ Answer 13
- Account FAQ Answer 14
- Account FAQ Answer 15
- Account FAQ Answer 16
- Account FAQ Answer 21
- China (Chinese)
- 更改国家/语言
Old Browser
Discover the BD FACSLyric™ Flow Cytometer difference.
- Witness results you have never seen before through high sensitivity and improved resolution
- Streamline your lab workflow through flexibility and automation, enabling efficiency and productivity
- Achieve automated standardization through highly reproducible results and enable collaboration through assay portability
See how the BD FACSLyric™ System can transform your lab.
The BD FACSLyric™ Flow Cytometry System—A Next-Generation Flow Cytometer
Built on a foundation of excellence, experience and expertise, the BD FACSLyric™ Flow Cytometry System is a new standard for cell analysis, transforming the way your lab does flow cytometry. As with all BD instruments, the BD FACSLyric™ Flow Cytometry System is backed by 40 years of BD expert training, service and support—so there’s no limit to your potential.
The Power of the BD FACSLyric™ Flow Cytometer
- 4-, 6-, 8-, 10- and 12-color configurations. Onsite upgradeable to adapt to your lab's changing needs
- Up to 3 lasers—blue, red and violet—12 fluorescence channels and 14 parameters
- 35,000 events per second maximum acquisition rate; no limit on number of events acquired
- Automated single-tube QC with BD® CS&T Beads
- Fluorescence compensation required only every 60 days, improving efficiency and productivity
- 21 different loading options: plates or tubes; built-in flexibility with BD FACS™ Universal Loader
- Powered by the BD FACSuiteTM Acquisition and Analysis Clinical Application, whose password protection, audit trail, electronic signatures and IQ/OQ procedures assist in supporting U.S, FDA 21 CFR Part 11 compliance
- BD FACSLinkTM Laboratory Information System (LIS) Interface and BD Assurity LincTM Remote Systems Management Software streamline your workflow and help improve productivity through seamless integration.
Get more information from the BD FACSLyric™ Flow Cytometer Brochure.
PERFORMANCE
A new standard delivering outstanding performance and standardization within and between instruments
The BD FACSLyric™ Flow Cytometry System is a high-performance, highly sensitive flow cytometer that demonstrates exceptional resolution and improved separation to make dim and rare cell populations easier to resolve.
Between-instrument reproducibility of target MFI values on the BD FACSLyric System
Lyse/wash assay settings were imported across 15 instruments to show effects of standardization on beads. The CVs of the fluorescence intensity across all channels varies by less than 15.3%. Daily QC with one lot of BD® Cytometer Setup & Tracking Beads was run on fifteen BD FACSLyric™ Flow Cytometers. For each instrument, the PMTV gains were automatically adjusted to meet the target values. BD® FC Beads acquired on each BD FACSLyric™ Instrument. The MFI of positive populations was measured for all parameters across all instruments. The %CV is shown. The data for this internal study were acquired using BD® FC Beads across 15 BD FACSLyric™ Instruments. Greater between-instrument variability could be observed when running biological samples, when using non BD reagents or when comparing fewer instruments. Highly reproducible results between instruments drive standardization.
Blue Laser | %CV |
FITC | 4.2 |
FITC | 4.2 |
FITC | 4.2 |
FITC | 4.2 |
Red laser | %CV |
FITC | 4.2 |
FITC | 4.2 |
FITC | 4.2 |
FITC | 4.2 |
Violet laser | %CV |
FITC | 4.2 |
FITC | 4.2 |
FITC | 4.2 |
FITC | 4.2 |
"BD is positioned with BD CS&T and BD® FC Bead technology to enable instrument standardization simply from day to day, instrument to instrument, and lab to lab."
"BD is positioned with BD CS&T and BD® FC Bead technology to enable instrument standardization simply from day to day, instrument to instrument, and lab to lab."
“The consistency and the regulatory compliance of FACSLyric [Flow Cytometer]’s output is what really drew us to the platform. It is currently unmatched by other flow cytometers in its ability to generate reliable, repeatable results across tests and instruments—even for the most complex assays we deal with day to day. We’ve found it particularly beneficial for multiparameter testing for CAR T cells and immunophenotyping.”
“The consistency and the regulatory compliance of FACSLyric [Flow Cytometer]’s output is what really drew us to the platform. It is currently unmatched by other flow cytometers in its ability to generate reliable, repeatable results across tests and instruments—even for the most complex assays we deal with day to day. We’ve found it particularly beneficial for multiparameter testing for CAR T cells and immunophenotyping.”
“The assay portability of BD FACSLyric is the key to efficient method transfer and high data reproducibility. It represents a clear advantage in a regulated environment, where conditions must be met to produce valid results of a guaranteed level of quality. Functional immune cell–based assays and cytokine quantification in preclinical and clinical drug development is a particularly important area where BD FACSLyric offers clear technical advantages.”
“The assay portability of BD FACSLyric is the key to efficient method transfer and high data reproducibility. It represents a clear advantage in a regulated environment, where conditions must be met to produce valid results of a guaranteed level of quality. Functional immune cell–based assays and cytokine quantification in preclinical and clinical drug development is a particularly important area where BD FACSLyric offers clear technical advantages.”
“The BD FACSLyric is a system for everyday work that every technician can use.”
“The BD FACSLyric is a system for everyday work that every technician can use.”
- Brochure
- Filter Guide
- Technical Specifications
- Product List
- Product Information Sheets
- Quick Reference Guide
- Webinars
- Application Note
- Posters
- 2016 ESCCA: Simplified Workflow using Automated Setup and Compensation
- 2016 ESCCA: Performance Evaluation of 10-color system with Tritest Reagents
- 2016 ESCCA: Enhanced Reproducibility of B Cell Assays Using Universal Assay Setup and Dry Reagents
- 2016 ICCS: Analysis of checkpoint Marker Expression Using a 10-color Assay
- 2017 CYTO: Long term CST set-up stability
- 2017 ESCCA: Checkpoint Expression on Immune Cells Using 12-color System
- 2017 ESCCA: 12-color Activation and Homing T reg Panel
- 2017 ICCS: Automated Instrument Setup and Compensation
- 2018 ESCCA: IP CD34 UK NEQAS Samples
- 2018 ESCCA: IP CLL UK NEQAS Samples
- 2019 ICCS: Development of a Dried-down, Multicolor Reagent Solution for Enhanced Flow-cytometric Applications
- Journal Publications
BD FACSLyric™ Flow Cytometers are Class 1 Laser Products.
The BD FACSLyric™ Flow Cytometer is for In Vitro Diagnostic Use with BD FACSuite™ Clinical Application for up to six colors. The BD FACSLyric™ Flow Cytometer is for Research Use Only with BD FACSuite™ Application for up to 12 colors. Not for use in diagnostic or therapeutic procedures.
Cy is a trademark of Global Life Sciences Solutions Germany GmbH or an affiliate doing business as Cytiva.
23-22842-00